Our house has a 3/4" PRV set to 65psi and the 3/4" irrigation line is connected after the PRV. When a zone turns on, the house water pressure drops significantly to ~40psi. I've measured the static and flowing pressure using a gauge in the basement piping and also measured at an external spigot. There are 6 RVAN 17'-24' heads on each of the zones, and I should be using around 6GPM which I've verified by watching the house water meter, so I don't think there is a big leak somewhere that's causing the issue.
The problem is that the heads don't pop fully up and the spray radius is only 17', and I need at least 20' to get even coverage. My guess is that the sprinklers are getting around 25psi after the pressure drops caused by the backflow preventer, piping etc.
Things I've checked:
PRV is a Watts LF25AUB-Z3. I've pulled it apart and checked the screen for debris, but didn't find anything. Also pulled apart the valve and spring but everything looked normal
I have one zone that is only 2 heads, and the pressure drops a lot less on that zone - maybe 2-5psi
If I hold one of the full circle RVAN heads closed while the zone is running, the water pressure measured in the house goes up by ~8psi
If I increase the PRV setting, the static pressure will go up to at least 80psi. I haven't tried to set it higher
If it matters, all the sprinkler bodies are 1800 PRS SAMs, 1" poly pipe used for the underground lines
Sprinkler system was DIY'd by my dad about 10 years ago and has had minimal upkeep since then
Can someone help explain why/where I'm losing pressure and how to fix it? Thanks in advance!