r/PLC 1h ago

Issues loading KS2000 on new laptop

Upvotes

Title says it all. I'm looking to see if anyone has had trouble installing KS2000 on their Windows 11 system, and if they were able to resolve it. I've gone and added the required windows features like HyperV, installing from an admin account, and modified the registry to disable incompatible services. Every time results in the same issue, the install bar fills completely and then the system just hangs on the full bar.

I don't want to write all the steps I've attempted, incase it discourages someone from suggesting something that I may have overlooked.

Thanks


r/PLC 2h ago

4-Pin to 8-Pin M12 Cable Suggestions???

1 Upvotes

Does anyone know of a (straight M12 4-pin A-Code male)-to-(straight M12 8-pin A-Code female) cable? Or connector?

I want to connect an IFM (LR8000) level sensor to a LUMBERG (RKF 4/0.5M) receptacle. Any suggestions are greatly appreciated!


r/PLC 3h ago

Data Center Controls Engineer

11 Upvotes

Was offered a role for I&C Engineer with a MEP engineering consulting firm.

What’s the work like? I’ve only ever been in manufacturing automation/systems integrations (PLCs, SCADA, Collab Robots) so I’m hoping to get a little insight.

Thanks!


r/PLC 6h ago

G120 absolute SSI encoder resets to zero on powerup

4 Upvotes

I have a bank of g120 drives connected to an SSI absolute multiturn encoder everything works untill a power cycle the drive it resets the position back to 0, any ideas on something I'm missing?


r/PLC 9h ago

Which servo platform would you choose today for a compacy XYZ machine?

4 Upvotes

I'm comparing options for small XYZ automation project and the old recommendations still seem to be Yaskawa, Mitsubishi, Omron, SEW, Kollmorgen, and Rockwell. What I’m less clear on is how people are choosing now when EtherCAT, cabinet space, diagnostics and multi-axis coordination matter more than they used to.

Would you still default to the established PLC-matched platform or consider something more specialized like Elmo Motion Control or Copley?


r/PLC 13h ago

Can a Siemens MTP400 Unified Basic connect directly to a Siemens LOGO! 8?

3 Upvotes

Hi,

Can a Siemens MTP400 Unified Basic (6AV2123-3DB32-0AW0) communicate directly with a Siemens LOGO! 8 12/24RCE (6ED1052-1MD08-0BA2)?

I'm using TIA Portal V19 and I can't find a LOGO! communication driver in the HMI connections.

Has anyone done this successfully?

Thanks!


r/PLC 17h ago

New EE with a focus in automation

1 Upvotes

Just went full time at the facility I interned with in college. I work in our maintenance department for the facility and they are allowing me to specialize in Controls and VFDs for the plant. I understand controls and VFDs pretty well the area I lack most in is Understanding the process of the facility. I work in the Pulp and Paper industry and was curious if anyone had tips or advice for an up and coming EE who wants to build a career in controls. Anything Helps. Thanks!

P.S.

Work mostly on Allen Bradley Products

My main area I lack in controls is the networking side of it


r/PLC 20h ago

Electrician to Automation

5 Upvotes

Currently an electrician and have been working in industrial controls for a couple years. And I think I want pursue automation work full time. Bought a micro850 and have been doing some small projects on my trainer set up at home. Thinking about going back to school for electrical engineering technology degree. Is it worth it to pair up with my electrical license?


r/PLC 22h ago

FT:Optix as Protocol Bridge

4 Upvotes

My chiller is ModbusTCP and I am monitoring some data in my FT:Optix project.
The core PLC is a Studio 5K project.
The thought crossed my mind of relaying some chiller data to the PLC.
I’m guessing it’s possible via a custom script but is it possible via a mapping function. Mapping Chiller:x into PLC:y

I know there are various options within Studio 5K for ModbusTCP but these are more work arounds and this isn’t that critical.


r/PLC 1d ago

Need help obtaining Rockwell's Connected Components Workbench

14 Upvotes

I am an chemist at a University who relies on a nitrogen generator with a Allen-Bradley Micro830 that is now giving me a blinking fault light. The manufacturer of this lab asset (Proton OnSite) was bought-out years ago, so there is no support. I can probably fix this thing if I could just find-out what the error is. I've tried downloading Connected Components Workbench (CCW) Standard Edition from Rockwell's website, but it won't let me download until I "request a location". I tried to add my location, but I can't do that because my University isn't already in their database. I can't find a way to enter my address.

My understanding is that this software is free and unlicensed. I just need it to read the fault and determine if I can fix my equipment. Can someone please guide me through how I can obtain access to this software?


r/PLC 1d ago

Modicon 484

Post image
73 Upvotes

Thought you guys might enjoy seeing this one. The cabinet is really still beautifully laid out even after all these years and being de-termed.
Never had the privilege to work on one of these myself. Not even sure what the programming interface would be.
The IO modules are super cool. Cast metal casing and they rock in and out of the rails simply by pushing down on the little red tabs. Wish things today were this well built.


r/PLC 1d ago

Early Career Controls/Automation Engineer seeking advice

2 Upvotes

I graduated as MechE and immediately started full time as a manufacturing automation/controls engineer with a large German energy and industrial automation company for about two years now. I’ve learned a lot and it is a highly regarded company but I just got offered a Instrumentation and controls engineer with a engineering consulting/construction firm, not as highly regarded in the automation world but it is a ~20% salary increase.

What should I do here?


r/PLC 1d ago

Follow-up on my Modbus tool - RTU/serial support landed, plus slave simulation and a scripting tab (v2.0.0)

Thumbnail
gallery
29 Upvotes

Posted here a while back about a small Modbus tool I built because I was tired of opening heavy clients just to read a few registers. Been chipping away at it since, and serial/RTU came up a lot in that thread (thanks u/MostEvilRichGuy and u/Automatater) - that's in now, along with a few other things.

Repo: https://github.com/CraftParking/ModbusLens

What's new in v2.0.0:

  • RTU/serial support - Connection Settings has a TCP/Serial switch now (COM port, baud, parity, stop bits)
  • Server mode - can run it as a TCP slave, so you can point your own PLC/SCADA program at it and test without real hardware
  • A small scripting tab for test sequences (write X, wait, read Y, repeat) - can target either a live connection or the local slave simulator
  • Trend graphing, tag-based alarms, CSV logging

Still just me building this around my own work, so a couple menu items are still placeholders. Grabbing the EXE from Releases works, no install needed.


r/PLC 1d ago

Please help - phantom Inputs blipping

1 Upvotes

Hello All,

I am onsite for my first startup as a small business. What was meant to be a simple panel swap for a shot blast machine has gotten complicated. Essentially I have a panel with 23 motor contactors, and I am just controlling the timed startup of these motors. I have a few inputs that are blipping (I can count them with counters in the code). Here is the weird part, the blipping stops when several of the motor contactors are turned on. The panel is feed with 480VAC **From a CAT Generator**, and then I have my 3kva control transformer creating 120VAC, and all the controls in the panel are 120VAC. This was required to interface with some existing IO. Why would pulling in multiple coils stop my inputs from blipping off momentarily?

I have even gone so far as to wire a spare circuit breaker directly to an input and it blips off occasionally when the system isn't running. Again, it doesn't do it when the motor contactors are pulled in.

Thanks for any suggestions!


r/PLC 1d ago

PLC on Silicone Mac?

0 Upvotes

Probably was asked before, and honestly I feel like the only answer is going to be that I cant do anything with a macbook but, i wanted to try my luck. I just started my internship at a factory, they manufacture machinary for meat products, etc and there automation uses mostly Inovance products. And.. well i have an m4 pro macbook and cant download codesys. i installed windows 11 on vmware fusion but i doubt it would work because of the drivers that are needed so on so forth. I thought maybe i could try openplc? the thing is i have no experience or info on any of this honestly. im fairly educated on computers though, and ive been using linux for a long time wine on top of that but really i was just fairly good at research and could find what i needed, i cant on anything plc related.

is there any way i could use this macbook for this internship or am i going to have to borrow a windows computer no matter what?


r/PLC 1d ago

Siemens s7-1200 RFID or barcode

8 Upvotes

I have an application where I have a siemens s7-1200 looking after a process that also has some human involvement.

The humans need to install some accessories before each time the process takes place. It is critical that the correct accessories are installed each time. At the moment, there are several layers of manual checking & documenting by different people before running the process - which is a pain!

I'm considering proposing streamlining the process by having the operator scan the accessories by RFID (with basic rfid sticker) or barcode/qr code as they are installed. This can then be displayed on an existing HMI for easier confirmation or possible automatically crosschecked against the plan.

Anyone have any recommendations on most straightforward hardware to use? System has its own private TCP/IP network so bonus points for making use of that! Thanks.


r/PLC 1d ago

Kinetix 6000

Post image
16 Upvotes

I'm currently replacing a Kinetix 6000 drive, and I'm running into some issues.

The new drive powers up fine, no errors show up. It's showing as enabled and no faults in Logix.

The servo will home after a power cycle, but will not home again after that.

These are for two feed screws, so I swapped the left and the right, and the problem followed the drive.

The only difference I can find is that the old drive is a "Series A" and the new one is a "Series C".

Did someone order the wrong drive? Or am I missing something glaringly obvious? Anyone have any experience with these?

Pic for reference. The top is the old one, bottom new.


r/PLC 1d ago

How to Wire a Dual-Channel Emergency Stop Switch to an EL1904?

5 Upvotes

Hello,

I'm new to Beckhoff PLCs and this is my first time working with a safety PLC.

I'm trying to connect an Emergency Stop switch to an EL1904 safety input terminal, but I'm having difficulty understanding the wiring.

I understand that a Category 4 safety circuit requires a dual-channel (redundant) E-Stop, but I'm not sure how each contact should be connected to the EL1904. Even after looking at the example wiring diagrams, I'm still confused about the actual wiring.

Could someone explain the wiring method or provide a simple example diagram showing how to connect a dual-channel Emergency Stop switch to the EL1904?

Thank you in advance for your help.


r/PLC 1d ago

Latest Marketplace Find

Thumbnail
gallery
110 Upvotes

Still has everything from when it was made in '85. Please excuse the red shop rag. The foam in the programmer slot is beyond expired, so I'm having to remove it.

Literally the only damage is the screws that hold the serial port into the programmer, and the foam in the programmer slot.


r/PLC 1d ago

Rebuild: CNC with a Delta controller

2 Upvotes

Good Afternoon

We are need of some help and hoping you are able to assist please?

We have had to rebuild our CNC with a Delta controller and  we have also put in new DELTA  drivers. 

The technician managed to obtain a sample program to convert Gcode motion controls using AX-816EP0CE1P to confirm the rebuild is accurate.

‒             .projectèAX8 code example

‒             .CNCè G code for testing

 

Our technician is using a DIAScreen to develop HMI application.

He is looking for help to display Gcode on the monitor connected to delta AX816EP0CE1P.

 

Is this something you are able to help us with?

We would appreciate recommendations/advice to get this machine running again


r/PLC 1d ago

HART/EDDL compiler issue: variable of type digital value should be float

1 Upvotes

Hello,
I’m developing an eddl file for a custom HART 7 device and run into a compiler error trying to map an internal a variable. In my eddl file the primary variable is a float value but the other variables are either bit_enumerated or integer type which the compiler cannot accept. I understand that the current compiler versions don’t accept bit_enums or other data types other than float. Is there a way to map these variables so that the compiler accepts it because I have seen in some earlier DD files ,variables have been declared as bit_enumerated especially for declaring device _status and other status codes. How would I be able to declare those variables for my device?
Appreciate any advice from DD developers.


r/PLC 2d ago

For those of you in Automotive

21 Upvotes

For those of you in automotive, is it normal for automation people in the field to have to do all of the mechanical side of things too? For instance, on part verification systems you have to build the brackets, mount the sensors, then do all of the wiring and programing.

Or when it comes to those, you have to do all of the PM's on them, but also fix all of the mechanical issues as well. Trying to figure out if it's just an industry standard that Automation / Controls people are just a maintenance mechanic with a laptop. Nothing wrong with that, it's just not my bag of beans. I'm trying to figure out if I just got a crap company or if I need to just avoid this field all together.

I'm used to and can see controls doubling up as electrical SME's or doing the complex electrical troubleshooting, but not all of the mechanical too.

I should specify that I'm really looking at internal roles, not contractor or SI type roles.


r/PLC 2d ago

FactoryTalk Optix combine two datalogger tables into one data grid

5 Upvotes

Hi all, I'm trying to combine the data from two loggers in a database to one "data grid" table by joining the rows together. My original plan was to use a SQL query, UNION or UNION ALL, to combine the rows, and according to Rockwell's own documentation FTOptix supports it. However, I could not find any instance of this being successfully implemented, I checked Rockwell's engage forums and only one person had the same issue as me and didn't mention a solution, leading me to believe there's an error in the documentation. Just wondering if anyone else has successfully used a UNION query in FTOptix SQL, or knows if it actually works or not? Or if anyone else has alternative methods to achieve the same functionality. Thanks


r/PLC 2d ago

PtP communication

4 Upvotes

Hello i have an upcoming project and i would like your opinions

I want to have two siemens logo plc talk to each other wirelessly over the distance of 3km mostly clear sight

I was thinking of using the ubiquity Powerbeam but I wasn't sure how reliable it is so I think I have settled to the AF-5XHD

I only want simple communication for a pump and reservoir automation

Would you choose something else something easier to setup?

I would love to hear your thoughts

Thanks!